Limitations of cyclic pile load tests by kentledge system in soft clay soil
Abstract
The paper describes the inadequacies of cycled head-down load tests on two barrettes and one bored pile installed in soft clay soil region in Binh Thanh district, and district 7, Ho Chi Minh City, Vietnam, respectively. The soil profile of these sites consisted of layers of organic soft clay and silt from 22.5 m to 28.6 m depth on compact silty sand or semi-stiff to stiff clays to about 60 m depth and followed by dense to very dense sand. The cross-section area of two barrettes located on the Tan Cang complex area was 2,800 mm by 800 mm, which were constructed using the bucket drill technique with bentonite slurry into 65 m depth. The bored pile of the Lakeside project in district 7 having a pile diameter was 1200 mm and 80 m depth. All instrumented piles were attached from ten to eleven strain gages levels along the pile shaft to record the deformation data during the load tests. The strain data analysis shows that the shaft frictions of pile portions located in the soft clay soil regions were increased dramatically, and the base resistances were smaller expected by the setting-up of Kentledge and the cyclic loading tests.
Keywords
Full Text:
PDFReferences
- S.-R. Kim, S.-G. Chung, B.H. Fellenius, Distribution of residual load and true shaft resistance for a driven instrumented test pile. Can. Geotech. J. 48(4) (2011) 583-598. doi:10.1139/t10-084.
- R.S. Nie, W.M. Leng, A.H. Wu, F.Q. Li, C.Y. Frank, Field Measurement and Analysis of Residual Stress in Bored Piles. J. Highway Transp. Res. Develop. (English Edition), 8(4) (2014) 57-62. doi:10.1061/JHTRCQ.0000411.
- R.S. Nie, W.M. Leng, Q. Yang, C.Y. Frank, Effects of Pile Residual Loads on Skin Friction and Toe Resistance. Soil Mech. Found. Eng. 55(2) (2018) 76-81. doi:10.1007/s11204-018-9506-4.
- H.M. Nguyen, A. Puppala, P. Ujwalkumar, L.V.H. Bach, Problem of cycled head-down pile load tests in soft soil region, in Proceedings of the Third International Conference on Geotechnics for Sustainable Infrastructure Development, Hanoi, Vietnam, 2016. pp. 157-162.
- B.H. Fellenius, Static tests on instrumented piles affected by residual load. J. Deep Found. Instit. 9(1) (2015) 11-20. doi:10.1179/1937525515Y.0000000001.
- B.H. Fellenius, B.N. Nguyen, Common mistakes in static loading-test procedures and result analyses. Geotech. Eng. J. SEAGS & AGSSEA 50(3) (2019) 20-31.
- INTRECO JSC, Soil Investigation Report of Tan Cang complex Project, Ward 22, Binh Thanh District, Ho Chi Minh, Vietnam, 2014.
- INVECO TECH. CORP., Soil Investigation Report of Lakeside tower project, Tan ThuanTay Ward, District 7, Ho Chi Minh, Viet Nam, 2011.
- COGECO Ltd., Report No. TT09BM01-02: Report on static load test of the barrette piles, Tan Cang Complex Project, 2014.
- COGECO Ltd., Report No. TT09BM05: Report on static load test of the bored pile, Lakeside tower Project, 2017.
- LamCarlos, J. A., Critical assessment of pile modulus determination methods. Can. Geotech. J. 48(10) (2011) 1433-1448. doi:10.1139/t11-050.
- B.H. Fellenius, Tangent modulus of piles determined from strain data. . The American Society of Civil Engineers, ASCE, Geotechnical Engineering Division, 1989 Foundation Congress, F. H. Kulhawy, Ed. vol. 1, pp. 500 - 510.
- B. Fellenius, Basics of foundation design. PileBuck International Inc. 2017.
Refbacks
- There are currently no refbacks.

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
ISSN 2170-127X

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Based on a work at http://revue.ummto.dz.