Experimental study of short concrete columns reinforced with GFRP bars under monotonic loading

An Vinh LE, Hiep Vu DANG, Duy Phan NGUYEN

Abstract


The glass fiber reinforced polymer (GFRP) bars are considered as an alternative reinforcement to steel in concrete structures subjected to chloride environment because of their non- corrosive and non-magnetic properties. To examine the applicability of GFRP bars to performance of concrete columns, this work was conducted. The effect of the compressive reinforcement ratio and stirrup spacing on the load carrying capacity of concrete columns reinforced with GFRP bars is experimentally investigated. Nine short concrete columns with dimensions of 150 × 150 × 600 mm were cast and tested until failure under displacement-controlled concentric loading. The experimental results demonstrated that by increasing the reinforcement ratio from 0.37% to 3.24%, the load-bearing capacity of GFRP RC columns was found to increase by an average of 28%. Moreover, the tested results confirmed that the GFRP stirrup spacing had a significant influence on the load-carrying capacity of the columns.


Keywords


Glass fiber reinforced polymer (GFRP) concrete column ultimate load tie spacing

Full Text:

PDF

References


- F.M. Antonio De Luca, N. Antonio, Behavior of Full-Scale Glass Fiber-Reinforced Polymer Reinforced Concrete Columns under Axial Load. ACI Struct. J. 107(5) (2010) 589-596. doi:10.14359/51663912.

- E. Lotfy, Nonlinear analysis of Reinforced Concrete Columns with Fiber Reinforced Polymer Bars. World J. Eng. 8(4) (2011) 357-368. doi:10.1260/1708-5284.8.4.357.

- J. Tu, K. Gao, L. He, X. Li, Experimental study on the axial compression performance of GFRP-reinforced concrete square columns. Adv. Struct. Eng. 22(7) (2019) 1554-1565. doi:10.1177/1369433218817988.

- A.C.I.C. 440. Guide for the Design and Construction of Concrete Reinforced with FRP Bars: ACI 440.1 R-03. American Concrete Institute, 2003.

- I.E.H. Ching Chiaw Choo, G. Hans, Minimum Reinforcement Ratio for Fiber-Reinforced Polymer Reinforced Concrete Rectangular Columns. ACI Struct. J. 103(3) (2006) 460-466. doi:10.14359/15325.

- FRP Viet Nam JSC, Technical Specifications of GFRP, Viet Nam. (2014).

- S. El-Gamal, O. AlShareedah, Behavior of axially loaded low strength concrete columns reinforced with GFRP bars and spirals. Eng. Struct. 216 (2020) 110732. doi:10.1016/j.engstruct.2020.110732.

- M.Z. Afifi, H.M. Mohamed, O. Chaallal, B. Benmokrane, Confinement Model for Concrete Columns Internally Confined with Carbon FRP Spirals and Hoops. J. Struct. Eng. 141(9) (2015) 04014219. doi:10.1061/(ASCE)ST.1943-541X.0001197.

- TCVN 5574:2012 Concrete and reinforced concrete structures - Design standard, in Ministry of Science and Technology, Vietnamese Standard. Vietnam, 2013.


Refbacks

  • There are currently no refbacks.




Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

ISSN 2170-127X

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Based on a work at http://revue.ummto.dz.